DRX-PR
PROCESS INPUT SIGNAL CONDITIONER
INPUT
TYPE
14V or 10V @ 25mA INPUT IMPEDANCE Voltage Range: 1Mohm Current Range: 10ohm ISOLATION Three way isolation up to 1800 V Peak for 1 minute, 354 V Peak continuous per IEC spacing Common mode rejection 100dB INPUT OVER-VOLTAGE PROTECTION Voltage input: 50V Current input: 50mA MODE Linear, Square root, Linear totalize, Square root totalize ANALOG TO DIGITAL TECHNIQUE Multiple slopes READ RATE 8 readings/second, automatic polarity ACCURACY AT 25 ░C ▒0.1% of FS ▒ 2 counts TEMPERATURE STABILITY 100 ppm/░C typical STEP RESPONSE FOR RS485 OUTPUT 2 seconds to 99% of the final value (Filter time constant = 64) RESPONSE TIME To verify the response time, check the carriage return i.e. send: *01X01 / response: 01X01
30 minutes INPUT POWER 10 to 32 Volt DC POWER CONSUMPTION 3 Watts (125 mA at 24 V DC) OPERATING AMBIENT -5 to +55 ░C STORAGE TEMPERATURE -40 to +85 ░C RELATIVE HUMIDITY 90% at 40 ░C non-condensing |